Low price supply of Tangshan positive pressure air supply outlet Dezhou Detong Air Conditioning Equipment Factory
search
|
home > sell > Low price supply of Tangshan positive pressure air supply outlet Dezhou Detong Air Conditioning Equipment Factory
Low price supply of Tangshan positive pressure air supply outlet Dezhou Detong Air Conditioning Equipment Factory
Details Low price supply Tangshan positive pressure air supply vent Dezhou Detong Air Conditioning Equipment Factory Tel. 3 is usually installed on the wall of the front room of the new elevator or the smoke exhaust shaft, and can also be installed on the side of the smoke exhaust system pipe or at the end of the air duct. Main functions and features: Normally closed, electric or manual opening. Output start signal. Manual reset off. ℃ temperature sensor operates and the valve closes again. The thin mechanism is adopted to reduce the size of the operation box and increase the effective ventilation and smoke exhaust area. 3 Main technical parameters Edit Action Voltage/Current:.. Air leakage volume:/·≤ (at pressure difference). Thermosensor operating temperature ℃. Structure editor main components: valve body, valve disc, bushing, thin actuator, grille panel. When B size ≥, assemble an actuator. Specifications and dimensions (×B×) [] Function: When a fire occurs, the electric actuator inside will open the air outlet, the temperature sensor smoke sensor or the manual fire alarm will turn on, and the positive pressure fan on the top of the tower will automatically turn on, which will affect the air supply shaft. For pressurized air supply, the front room of the stairs will continuously supply air to the front room through the positive pressure air supply port to maintain positive pressure in the front room to ensure that smoke will not spread in this area and give people space to escape. When the temperature is higher than ℃, there is no possibility for people to escape. The internal fuse will blow and the air vent will automatically close to prevent the spread of fire. Application: The national fire protection and smoke exhaust design specifications for high-rise buildings stipulate that the following locations should be equipped with independent mechanical smoke exhaust systems, smoke-proof stairs that do not have natural smoke exhaust conditions, and fire elevator front rooms or shared front rooms. , Use smoke-proof stairs with natural smoke exhaust, which do not have a front room with natural smoke exhaust. Enclosed refuge floor.
A total of0articles Related Comments: |